FDOE=DISABLED, MON=DISABLED, ASM=NORMAL, CCE=PROTECTED, TEST=DISABLED, BRSE=DISABLED, DAR=AUTO_RETX, CSR=NO_CLOCK_STOP, INIT=DISABLED
CC Control Register
| INIT | Initialization (read/write) 0 (DISABLED): Normal operation. 1 (ENABLED): Initialization is started.  |  
| CCE | Configuration Change Enable (read/write, write protection) 0 (PROTECTED): The processor has no write access to the protected configuration registers. 1 (CONFIGURABLE): The processor has write access to the protected configuration registers (while MCAN_CCCR.INIT = ‘1’).  |  
| ASM | Restricted Operation Mode (read/write, write protection against ‘1’) 0 (NORMAL): Normal CAN operation. 1 (RESTRICTED): Restricted Operation mode active.  |  
| CSA | Clock Stop Acknowledge (read-only)  |  
| CSR | Clock Stop Request (read/write) 0 (NO_CLOCK_STOP): No clock stop is requested. 1 (CLOCK_STOP): Clock stop requested. When clock stop is requested, first INIT and then CSA will be set after all pend-ing transfer requests have been completed and the CAN bus reached idle.  |  
| MON | Bus Monitoring Mode (read/write, write protection against ‘1’) 0 (DISABLED): Bus Monitoring mode is disabled. 1 (ENABLED): Bus Monitoring mode is enabled.  |  
| DAR | Disable Automatic Retransmission (read/write, write protection) 0 (AUTO_RETX): Automatic retransmission of messages not transmitted successfully enabled. 1 (NO_AUTO_RETX): Automatic retransmission disabled.  |  
| TEST | Test Mode Enable (read/write, write protection against ‘1’) 0 (DISABLED): Normal operation, MCAN_TEST register holds reset values. 1 (ENABLED): Test mode, write access to MCAN_TEST register enabled.  |  
| FDOE | CAN FD Operation Enable (read/write, write protection) 0 (DISABLED): FD operation disabled. 1 (ENABLED): FD operation enabled.  |  
| BRSE | Bit Rate Switching Enable (read/write, write protection) 0 (DISABLED): Bit rate switching for transmissions disabled. 1 (ENABLED): Bit rate switching for transmissions enabled.  |  
| PXHD | Protocol Exception Event Handling (read/write, write protection)  |  
| EFBI | Edge Filtering during Bus Integration (read/write, write protection)  |  
| TXP | Transmit Pause (read/write, write protection)  |  
| NISO | Non-ISO Operation  |